Choosing between CWDM and DWDM for an access or metro upgrade comes down to how the two products divide the optical spectrum and how much loss each adds at the channel count you actually need to light. The CWDM series works on a 20 nm wavelength grid; the DWDM series works on the C and L band ITU grid at 100 GHz or 200 GHz. The 20 nm grid was set wide enough for uncooled transmitters and wide-passband filters, which is why it became the standard way to add a handful of wavelengths to an access link, while the dense grid is built for links where many channels share one span and transmitter frequency is held steady. What decides the fit is the channel count on the span, the number of mux stages between the transmitter and the receiver, and the insertion loss the data sheet gives for that channel count. The table below is read per channel count, not as one figure for the whole series.
What separates the two series
Both products multiplex several wavelengths onto one fiber and separate them again at the receiving end. The difference sits in how finely the spectrum is divided. The CWDM series divides it in wavelength steps of 20 nm; the DWDM series divides C and L band on the ITU grid in 100 GHz or 200 GHz steps.
ITU-T G.694.2 explains why the coarse grid looks the way it does: the nominal central wavelength spacing was set at not less than 20 nm so that uncooled sources and wide-passband filters could carry several wavelengths at once, and total source wavelength variation of the order of +/-6-7 nm is expected to be compatible with current filter technologies. Its table lists nominal central wavelengths in 20 nm steps from 1271 nm to 1611 nm, and the 12/2003 edition moved that grid by 1 nm to line up with industry practice.
ITU-T G.694.1 anchors the dense grid at 193.1 THz and defines channel spacings from 12.5 GHz upward. The same Recommendation states that DWDM transmitters generally need a control mechanism to meet the application's frequency stability requirements, whereas CWDM transmitters are generally uncontrolled in that respect. That is the practical heart of the comparison: at 20 nm spacing the module can be forgiving of an ordinary uncooled laser, and at 100 GHz the whole link is held to a tighter frequency.
Reading the parameters per channel count
The insertion-loss rows are maximum values printed per channel count. A 2-channel part and an 8-channel part belong to the same series but do not share one loss number, and neither series can be summarised into a single figure for the whole line.
| Parameter | CWDM series | DWDM series |
|---|---|---|
| Channel spacing | 20 nm | 100 GHz or 200 GHz, C and L band ITU grid |
| Channel bandwidth, CWDM | λc ± 6.5 nm | — |
| Max insertion loss, 2 channel | ≤1.6 dB | ≤1.6 dB |
| Max insertion loss, 4 channel | ≤2.4 dB | ≤2.4 dB |
| Max insertion loss, 8 channel | ≤2.5 dB | ≤2.5 dB |
| Adjacent channel isolation | ≥30 dB | ≥30 dB |
| Non-adjacent isolation | ≥45 dB | ≥45 dB |
| Return loss | ≥45 dB | ≥45 dB |
| PDL / PMD | ≤0.1 dB / ≤0.1 ps | ≤0.1 dB / ≤0.1 ps |
| IL temperature coefficient | ≤0.005 dB/°C | ≤0.005 dB/°C |
| Operating / storage temperature | 0-70 °C / -40-85 °C | 0-70 °C / -40-85 °C |
| Package | 80 × 58 × 6.6 mm | 80 × 58 × 6.6 mm |
Up to eight channels the two series carry the same rated maximum: both are specified at ≤1.6 dB for two channels, ≤2.4 dB for four and ≤2.5 dB for eight. On paper, then, a design that stays within eight channels is not asked to pay more multiplexing loss for the coarse grid. Those are data-sheet limits, not measurements of any particular unit, so what a delivered part adds still comes from its own test report.
What the port labels of a CWDM module show
The label column on an eight-channel CWDM module is the quickest place to confirm the spacing you are planning. The unit in the photo carries a COM port and eight ports marked 1470, 1490, 1510, 1530, 1550, 1570, 1590 and 1610, each one 20 nm from the previous label. That is what a coarse-grid part looks like in hardware: eight wavelengths spread over 140 nm, rather than eight packed into a fraction of one band.
The G.694.2 table lists nominal central wavelengths as a reference set of grid positions across the 1271 to 1611 nm range; it does not say how many ports any module carries, and the values printed on a module's own label are that module's configuration. Our CWDM page lists series modules up to 16 channels and the DWDM page lists its own range, so an order states ports and spacing together rather than inferring one from the other.
Spacing changes how the spectrum is shared
An eight-port module and a sixteen-port module differ in how many wavelengths they separate, and that is a different question from how much of the fiber's spectrum those wavelengths occupy. The coarse grid hands out 20 nm of nominal spacing per channel, so a CWDM design has a wide tuning range to draw on and takes a long slice of the fiber's spectrum; the dense grid packs its channels inside C and L band, where optical amplifiers and add-drop units operate.
The DWDM demux in the photo is labelled 8+1CH 100G DWDM Demux, a label that names its channel count and its spacing family on one line. That is the form a bill of materials should be checked against: two modules with the same number of ports at different spacings are not interchangeable parts, and a plan drawn for 100 GHz and one drawn for 200 GHz are different plans.
Where each series fits
On the access side the number of wavelengths is set by the services a node has to carry, and a single mux is asked to put a handful of them on one fiber. Our CWDM page positions the series exactly there, as a low-cost WDM technology for the access layer of metropolitan area networks. A 20 nm grid, uncooled sources and a maximum of 3.5 dB at sixteen channels fit that job, and the CWDM series page carries the full table.
The dense series is aimed at a different setting. Our DWDM page names where 100 GHz and 200 GHz parts are used: the fiber amplifier, OADM and OTC functions of DWDM systems, and DEDM technology in power systems. Those are link architectures where many wavelengths share one span and the optics around the mux are built for C and L band. G.694.1's point about transmitter frequency control is the reason that architecture and the module belong together: a dense plan only holds if the transmitters hold the grid. The DWDM series page is the part of our catalogue that belongs in such a design.
Between the two sits the case that catches most budgets: a metro node that has outgrown the ports on its working mux while its transceivers, spares and test sets are all built around the coarse grid. Changing the mux alone does not change the ceiling; it changes it only for equipment that can also hold the dense frequency. A coarse-grid transceiver pointed at a DWDM port will not hold 100 GHz channel spacing, and a CWDM module cannot serve as a DWDM stage. The mux decision and the transmitter decision belong to the same equipment list.
Keeping the mux out of the loss budget deficit
Insertion loss only becomes a decision when you know how often the signal passes through a mux and what else is already charged against the link. FOA's guidance on fiber optic loss budgets is explicit that a link works only when the cable-plant loss falls inside the link's power budget, that passive loss includes fiber, connectors, splices and any couplers or splitters, and that a calculated budget is an estimate that needs margin.
On an access route the mux is one more passive element in that sum, next to fiber attenuation, patch-cord connectors and any splitter already in the path. A single 16-channel CWDM stage at ≤3.5 dB is modest against a link with headroom; two mux stages in series are two losses to add, because the signal passes each one. Count the stages that sit between the transmitter and the receiver, read the row for the channel count of each stage, and put that total into the budget with the same margin you give the rest of the plant.
That is also where the channel count stops being a neat round number. A budget built on eight channels and then expanded to sixteen needs the new row, not the old one, because the sixteen-channel state of a series is specified separately from its eight-channel state.
Two numbers that stay the same
Both series share an 80 × 58 × 6.6 mm package and the same 0-70 °C operating range, with storage rated from -40 to 85 °C. PDL ≤0.1 dB, PMD ≤0.1 ps, return loss ≥45 dB and the temperature coefficient of ≤0.005 dB/°C are also common to both tables.
None of those figures decides between the two products. Shared values describe each series against its own specification; they are not a statement that a part from one series can stand in for a part from the other in an installed link. What moves between the two is the spacing, the band each module works in, and the transmitter stability each grid demands. The G.695 referenced on the CWDM page is the Recommendation for coarse WDM optical interfaces; it belongs with the grid, not with any comparison of dense and coarse parts.
Choosing for the link you are building
Start from the channel count the node has to carry and the loss the mux will add at that count. Up to eight channels, the two series carry the same rated maximum, so the coarse grid gives the same budget room with a wider nominal spacing.
Then look at what else the link carries. If the route is built around amplifiers or add-drop stages and the optics are dense-grid parts, the DWDM series is the family that belongs in that design, and the coarse grid would need its own transmitter and channel plan to work at all. If the link is an access route with uncooled optics and a mux at each end, the CWDM series is the simpler fit, and its loss is what you budget.
Write the spacing into the order as well as the port count. The spacing and channel count are what the loss figures are keyed to, so a bill of materials that names both is the one the budget can be checked against.
——END——